Thank you for your continued patronage of
this company.
Mistakes undertaken during refueling of
hydraulic pressure oil in our company’s air riveters can result in damage to
the machine body and effect performance. With this in mind, the following
information has been included in instruction manuals, and we ask our customers
to please take note of the operation as indicated.
 
[Cautionary notes uniform to various models]
• Be sure to stop the air supply before
operation.
• Use LOBSTER Hydraulic Pressure Oil B10012
for the oil.
• After refueling oil, be sure to confirm
that there is no loosening of items in each of the jaw case sections.
• During operation, be sure to use the
proper air pressure (0.5–0.6 MPa)
 
Operate only after confirming operation is
in line with the points of caution described in the instruction manual* for the
given machine.
(Please contact us if the model you are
using is not listed below)
* The instruction manual is available for
viewing by clicking the model listed below. (Only the models that are
underlined are available)
 
    
        
            | Model | Points of Caution 
 | 
        
            | R1A1 R1A2
 | • Be sure to remove the frame head before refueling. • Confirm that none of the parts in the vicinity of the jaw case are loose.
            • After refueling and replacing the frame head, loosen the oil retaining screw section and remove excess hydraulic oil.
 |  | 
        
            | AR-011S AR-011M
 AR-011H
 AR-011MX
 AR-011HX
 ARV-011M
 ARV-015S
 | • Be sure to remove the frame head before
            refueling. • After refueling, confirm that the jaw
            case is in its set position, and that none of the related parts are loose. | 
        
        
        
            | ARV-015M ARV-015MX
 | • Be sure to remove the frame head before
            refueling. • After refueling, loosen the oil retaining
            screw section and remove excess hydraulic oil. • After removing the excess hydraulic oil,
            confirm that the jaw case is in its set position, and that none of the related
            parts are loose. | 
        
            | AR-2000S AR-2000M
 AR-2000H
 AR-2000SV
 AR-2000MV
 AR-2000HV
 | • Be sure to remove the frame head before
            refueling. • After refueling, loosen the oil retaining
            screw section and remove excess hydraulic oil. • After removing the excess hydraulic oil,
            confirm that the jaw case is in its set position, and that none of the related
            parts are loose. | 
        
            | AR-3000EV | • Be sure to remove the frame head before refueling. • After refueling using the oil feeder, firmly close the oil retaining screw and pull out the oil piston.• Loosen the oil retaining screw and remove any excess hydraulic oil from the exposed oil piston. 
 | 
        
            | AR-022M ARV-022M
 ARV-025M
 | • Remove the cap or oil tank cap, and fill
            the rubber tank. • When the rubber tank is in a slightly
            collapsed state, this is the correct oil amount • After refueling, confirm that none of the
            parts related to the jaw case are loose. | 
        
            | Angle RiveterAR2000A-90
 AR2000A-45
 AR2000A-00
 
 | • Before refueling, be sure to remove the angle head frame.• After refueling, be sure to loosen the oil retaining screw and remove any excess hydraulic oil. 
 | 
    
 
If any of the above points are unclear, please consult our call center for more information.
 
Lobtex Co., Ltd. Call Center               TEL 072-980-1111    FAX 072-980-1166